Resistance is Futile

GRF04 (Custom)

Fried:  A cell dies during a charge and takes out a cell-circuit on the Battery Management System

The thing about Lithium cells is that they have to be treated with a certain amount of care and respect. You should get plenty of notice if cells are deteriorating. Weak cells throw the pack out of balance, taking longer to charge, and losing their charge more easily, lowering the capacity of the battery pack and the mileage you can get between charges. A while back, I finally got the cell-level LVC circuit of my Fechter Goodrum BMS up and working with my throttle and a warning light on my dash. If any cell goes below a certain threshold, a red warning light comes on permanently as an urgent alert to check my pack or give it a good charge. Since I typically recharge my pack well before it shows signs of flagging, I had hardly gotten to see it in action.

But one day when I was about to nip off to the supermarket I noticed that it was on. Checking the pack, I found that a slightly weak cell-pair had suddenly become a very weak cell-pair. This was one of the casualties from running the pack without an LVC system for so long, – I’d had to replace some cell-pairs when I’d run the pack almost flat a couple of times by accident (albeit over a 3 year span), but there was still one pair that was a little on the weak side but still serviceable.

So when the little red light came on  I was not entirely surprised, – the damage it had taken a couple of years earlier had finally caught up and the cell-pair was on its way out. If I’d been sensible, I’d have just pulled the pack there and then and taken the bike off the road, but I’d become quite dependent on the bike so thought I would run it a bit longer while I ordered a replacement pair of LiFePO4 cells.

Unfortunately, though, this isn’t such a good idea, as if you’re charging a pack and a cell-pair dies for good, this can result in damage to the BMS. So when, a couple of charges later, I noticed the charger was taking longer than usual, I should have unplugged everything sharpish rather than just leaving it to terminate of its own accord, which – in this case – meant turning the BMS’s corresponding cell-circuit turn into a giant fuse, burning most of its components to a crisp until the charger cut off automatically when it all shorted out. Taking the pack apart, the cells were clearly in quite a bad way.

GRF02 (Custom)

A very dead LiFePO4 38140S cell from my pack

The cells themselves weren’t really the issue here, though. The real problem was the blowback onto my beloved, home-built BMS. The main FET had initially born the brunt of it, burning itself to a crisp and leaving the big resistors on the back looking a bit ashen.

GRF03 (Custom)

The big resistors were still apparently alive, but given their condition (and the fact that they’re pretty cheap) I elected to replace them with other affected components. The capacitor here was also toast.

GRF04 (Custom)

The poor little 48.7KΩ and 220Ω resistors are almost totally destroyed. I think that as soon as the FET had burnt out and shorted, the power that would ordinarily be burned off as heat through the big resistors was channeled to the little resistors, which were pretty much totally destroyed. That – in turn – would have triggered the charger to shut down either via a signal from the BMS control circuitry, or the charger’s own safety cut-off. Either way, the charger checks out okay, so all I had to do was fix the circuit.

GRF05 (Custom)

Resistance is futile: Two of the 1/8W resistors are totally incinerated

My basic game plan for fixing the circuit was simple enough: Replace anything clearly burnt to a crisp, test other components and replace any obviously defective ones, then run resistance tests across the circuit until I got a result very similar to that across other cell circuits. One of the good things about these boards (Fechter Goodrum v4) is you really don’t need to know much about how they work to fix them: you can compare resistance meter and continuity readings between various bits of a dead circuit, and then compare those readings to any of the neighbouring circuits that are working. If you don’t get the same resistance readout across your circuit after replacing something, then just keep replacing things until you do!

So once my Mouser order was in for some spare cell-circuit components,  I went ahead and started replacing components. First, I switched the main FET and the two resistors. Next I pried out the incinerated little resistors and cleaned up the surrounding area with wire cloth.  I also took out the dead capacitor. For reference, here’s a little map of the components further down:

circuit

 

GRF06b (Custom)

I took the FAN431 next to the frazzled resistors out too, as well as the diode, then replaced the top diode and resistors with fresh ones.

GRF06d (Custom)

Next, in went a fresh FAN431.

GRF06e (Custom)

The 2906 transistor was shorted so I removed that and the 47Ω resistor next to it, which was also burned out. The TC54 transistor next to it came out too, since replacing all the the 2906 and all the other stuff still hadn’t restored the correct resistance readings for the circuit.

GRF07b (Custom)

With the 2906 and the TC54 transistor replaced I just had one problem: The 47Ω resistor was on back order, and not due in for another couple of weeks. Fortunately this didn’t affect my ability to test the circuit, I just temporarily stuck a larger 1/4W resistor of the same value into the holes to check the circuit. I’m getting all the right readings, now and it looks all ready for a proper test.  I just have to wait for that one little set of 47Ω 1/8W  resistors to arrive in the mail.

GFR08 (Custom)

All done, except for that one resistor

For anyone interested in joining the exciting world of homemade battery management systems, check out my thread for the Fechter Goodrum “Zephyr” 4.4 boards, which I also sell in my shop.  I’ve had mine for nearly four years now, and this is the first time I’ve managed to do any damage to it.

The take home message from this is of the stitch-in-time-saves-nine variety: There’s little point in having a great, cell-level, LVC system and battery monitor that warns you of weakening cells if you don’t heed the warning signs and red lights and keep chancing it with further recharges. Change weak cells sooner rather than later, don’t tempt fate by ignoring the warning signs of a dying cell-pair, and don’t continue to charge them until they die right in the middle of a charge cycle.

4 Responses to Resistance is Futile

  1. Davina says:

    Hiya. Firstly do you live anywhere near Derby? I would love for you to have a look at my bike. :). But could you tell me if the problem I’m having is due to my speed controller box please? There’s just no power the minute I put the back wheel on the ground with any weight on it. Thank you for your time. Davina 🙂

    Sent from my iPhone

    >

    • zenid10 says:

      Hi Davina, Like I say, it could be the controller (I assume that’s what you mean by “speed controller box”) or the motor, you have to test them. Start with the motor test I describe in my blog. What’s the pack voltage? What’s the battery type – Lead-acid or Lithium pack? Yes, I do live quite close to Derby, but my bike’s off the road at the moment while I fix the BMS.

      • Davina says:

        Hiya so sorry for the delay in getting back :). First it’s a 48v 1500w bike. I’m not sure what the batteries are. But I know the batteries are fine. They was the first thing that I checked with a mega meter. I was reading in your blog about some senses in the back wheel. Could you please tell me what they are called please so I can look them up. Plus I was on about the transmitter under the bike when I was writing about speed controller. 🙂
        So sorry to hear yours is off the road has well 😦 Hope it’s nothing to serious?
        Thank you again for getting back and your time.
        Davina 🙂

  2. zenid10 says:

    Hi Davina,

    Full details about the hub motor and hall sensors are in the “hub motor diagnosis and repair” entry:
    https://zenid10.wordpress.com/category/4-how-to-guide/4-9-hub-motor-diagnosis-and-repair/
    Could you post any further queries in the “Ask Zenid” section (tab top right).

    I’m nearly ready to put the bike back on the road now. I was waiting on one last part to repair the BMS. Right now, I’m testing it and breaking in some new cells with gentle charge-cycling. I’m just waiting for some fresh perspex for the battery pack, then I can put it all back together. It needs and MOT though, too, as the old one’s expired.

    Zenid

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out /  Change )

Facebook photo

You are commenting using your Facebook account. Log Out /  Change )

Connecting to %s

%d bloggers like this: